§ 8-135. Authorizing connection of natural gas to mobile homes.  


Latest version.
  • Natural gas may be connected to a mobile home providing the following procedure and safety regulations are complied with:

    (1)

    All provisions of this article;

    (2)

    Mobile homes shall be solidly blocked with jacks or suitable blocking with open spaces not to exceed ten feet;

    (3)

    Mobile homes shall be anchored to prohibit movability with not less than four anchors;

    (4)

    That an iron-bodied, brass core shut-off cock not less than one inch thread size shall be placed on the riser as near as possible above ground level;

    (5)

    That the connector from the break-away nipple to the mobile home shall be approved A.G.A. flexible connector (self-identified) not smaller than three-fourths inch I.D. size and not exceeding six feet in length.

(Code 1973, § 4-419; Ord. No. 4170, § 1, 12-18-84)